MIB Information: uchasPowerSupply
1.3.6.1.4.1.429.1.1.4
MIB Information: uchasPowerSupplyTable
1.3.6.1.4.1.429.1.1.4.1
not-accessible
Description: A list of power supply entries one for each power supply in the chassis. This table is a dense table so rows appear for all possible power supplies that could be present in the given chassis.
MIB Information: uchasPowerSupplyEntry
1.3.6.1.4.1.429.1.1.4.1.1
not-accessible
Description: There is one entry in the power supply table for each possible power supply in the chassis.
MIB Information: uchasPowerSupplyIndex
1.3.6.1.4.1.429.1.1.4.1.1.1
optional read-only
Description: An index value that uniquely identifies a power supply.
Settings: INTEGER
MIB Information: uchasPowerSupplyDescr
1.3.6.1.4.1.429.1.1.4.1.1.2
optional read-only
Description: A textual description of the power supply.
Settings: DisplayString
Syntax Ref. Type: SIZE
0 = 124
MIB Information: uchasPowerSupplyOperStatus
1.3.6.1.4.1.429.1.1.4.1.1.3
optional read-only
Description: Actual status of the power supply represented by this entry in the power supply table.
Settings: INTEGER
Syntax Ref. Type: ENUM
(1) = unknown
(2) = bad
(3) = good
(4) = empty
MIB Information: uchasPowerSupplyFailures
1.3.6.1.4.1.429.1.1.4.1.1.4
optional read-only
Description: The number of times that uchasPowerSupplyOperStatus has gone to bad(4).
Settings: Counter
MIB Information: uchasPowerSupplyOutTable
1.3.6.1.4.1.429.1.1.4.2
not-accessible
Description: A list of power supply output entries one for each output of each power supply in the chassis.
MIB Information: uchasPowerSupplyOutEntry
1.3.6.1.4.1.429.1.1.4.2.1
not-accessible
Description: There is one row in this table for each power supply output for each power supply in the chassis.
MIB Information: uchasPowerSupplyOutPSIndex
1.3.6.1.4.1.429.1.1.4.2.1.1
optional read-only
Description: An index which specifies the power supply to which this output relates. The value of this index corresponds directly to values of the index for the power supply table.
Settings: INTEGER
MIB Information: uchasPowerSupplyOutIndex
1.3.6.1.4.1.429.1.1.4.2.1.2
optional read-only
Description: An index that together with uchasPowerSupplyOutPSIndex uniquely defines an output for the specified power supply.
Settings: INTEGER
MIB Information: uchasPowerSupplyOutStatus
1.3.6.1.4.1.429.1.1.4.2.1.3
optional read-only
Description: Actual status of the supply output. One of unknown(1) warning(2) or good(3).
Settings: INTEGER
Syntax Ref. Type: ENUM
(1) = unknown
(2) = warning
(3) = good
MIB Information: uchasPowerSupplyOutNominalVolt
1.3.6.1.4.1.429.1.1.4.2.1.4
optional read-only
Description: In hundredths of a volt the voltage the output is supposed to supply such as -5V which would be represented by the value -500 or +12V which would correspond to a value of +1200.
Settings: INTEGER
MIB Information: uchasPowerSupplyOutOfferedVolt
1.3.6.1.4.1.429.1.1.4.2.1.5
optional read-only
Description: In hundredths of a volt the voltage actually offered by the output. If uchasPowerSupplyOutStatus is good(4) the value 0 means offered voltage is not available.
Settings: INTEGER
MIB Information: uchasPowerSupplyOutWarnings
1.3.6.1.4.1.429.1.1.4.2.1.6
optional read-only
Description: The number of times uchasPowerSupplyOutputStatus has gone to warning(3).
Settings: Counter