MIB Information: hdmLi
1.3.6.1.4.1.429.1.22.1
MIB Information: hdmLiTable
1.3.6.1.4.1.429.1.22.1.1
not-accessible
Description: A list of configurable Line Interface objects for a modem. The number of table entries is given by modemNumber.
MIB Information: hdmLiEntry
1.3.6.1.4.1.429.1.22.1.1.1
not-accessible
Description: Objects which define the line interface characteristics for a particualar modem.
MIB Information: hdmLiIndex
1.3.6.1.4.1.429.1.22.1.1.1.1
mandatory read-only
Description: Index into the Line Interface table. This index is the value from the chassis mib entity relation table that is applicable for a particular modem.
Settings: INTEGER
MIB Information: hdmLiIndex2
1.3.6.1.4.1.429.1.22.1.1.1.2
mandatory read-only
Description: Secondary Index into the Line Interface table. This index is the value from the chassis mib entity relation table that is applicable for a particular modem.
Settings: INTEGER
MIB Information: hdmLiDialPause
1.3.6.1.4.1.429.1.22.1.1.1.3
mandatory read-write
Description: Duration in seconds for the pause(') option in the dial command and the pause between command re-executions(> and A>) Default = 2. Equates to the modem's S8 register.
Settings: INTEGER
Syntax Ref. Type: RANGE
0 = 255
MIB Information: hdmLiCarrierRecDelay
1.3.6.1.4.1.429.1.22.1.1.1.4
mandatory read-write
Description: Duration in 10ths of a second that the remote modem's carrier signal must be present before recognition. Ignored at speeds above 2400. Equates to the modem's S9 register. Default=6.
Settings: INTEGER
Syntax Ref. Type: RANGE
0 = 255
MIB Information: hdmLiCarrierLoss
1.3.6.1.4.1.429.1.22.1.1.1.5
mandatory read-write
Description: Duration in 10ths of a second the modem waits after loss of carrier before hanging up. This allows the modem to distinguish between a momentary lapse in line quality and a true disconnect. When equal to 255 the modem will remain off hook until DTR drops or an ATH command is received. Equates to the modem's S10 register. Default=7.
Settings: INTEGER
Syntax Ref. Type: RANGE
0 = 255
MIB Information: hdmLiToneDialTiming
1.3.6.1.4.1.429.1.22.1.1.1.6
mandatory read-write
Description: Duration and spacing in milliseconds of dialed Touch Tones. Equates to the modem's S10 register. Default=70.
Settings: INTEGER
Syntax Ref. Type: RANGE
0 = 255
MIB Information: hdmLiGuardTone
1.3.6.1.4.1.429.1.22.1.1.1.7
mandatory read-write
Description: This object is required for modems answering calls that originate from sites outside of North America. The modem's must be operating in either 1200 or 2400 bps and be using the V.32 answer sequence. This object defines what guard tone is used for answering calls. This object equates to the &G register in US Robotics modems. Default=none.
Settings: INTEGER
Syntax Ref. Type: ENUM
(1) = none
(2) = european550
(3) = uk1800
MIB Information: hdmLiAnswerTone
1.3.6.1.4.1.429.1.22.1.1.1.8
mandatory read-write
Description: Disables the 2100 Hz Answer tone allowing V.42 modems to connect more quickly and/or eliminating problems with older 2400-bps modems that do not recognize this tone. Equates to the modem's S27.3 register. Default=Enabled.
Settings: INTEGER
Syntax Ref. Type: ENUM
(1) = enable
(2) = disable
MIB Information: hdmLiTransmitLevel
1.3.6.1.4.1.429.1.22.1.1.1.9
mandatory read-write
Description: Specifies the signal level of the modem transmitter in negative dB.
Settings: INTEGER
Syntax Ref. Type: RANGE
0 = 20
Copyright © 2000 3Com Corporation.