MIB Information: mds1Cfg
1.3.6.1.4.1.429.1.36.1
MIB Information: mds1CfgTable
1.3.6.1.4.1.429.1.36.1.1
not-accessible
Description: The DS1 Configuration table
MIB Information: mds1CfgEntry
1.3.6.1.4.1.429.1.36.1.1.1
not-accessible
Description: An entry in the DS1 Configuration table.
MIB Information: mds1CfgIndex
1.3.6.1.4.1.429.1.36.1.1.1.1
mandatory read-only
Description: The index value which uniquely identifies the CSU to which this entry is applicable.
Settings: INTEGER
MIB Information: mds1CfgIface
1.3.6.1.4.1.429.1.36.1.1.1.2
mandatory not-accessible
Description: One of 4 spans on this MCP card.
Settings: INTEGER
MIB Information: mds1CfgCBSCNum
1.3.6.1.4.1.429.1.36.1.1.1.3
mandatory read-write
Description: This object identifies the CBSC number attached to this interfaceINTEGER.
Settings: INTEGER
MIB Information: mds1CfgFRConfgType
1.3.6.1.4.1.429.1.36.1.1.1.4
mandatory read-write
Description: One of the following configurations Types:(1) B Channel(2) H0 (3) Nailed Up.
Settings: INTEGER
Syntax Ref. Type: ENUM
(1) = bChannel
(2) = h0
(3) = nailedUp
MIB Information: mds1CfgFRConfgTypeOpr
1.3.6.1.4.1.429.1.36.1.1.1.5
mandatory read-only
Description: One of the following configurations Types:(1) B Channel(2) H0 (3) Nailed Up. This is the operational value.
Settings: INTEGER
Syntax Ref. Type: ENUM
(1) = bChannel
(2) = h0
(3) = nailedUp
MIB Information: mds1CfgLineType
1.3.6.1.4.1.429.1.36.1.1.1.6
mandatory read-write
Description: This variable indicates the variety of DS1 Line implementing this circuit. The type of circuit affects the number of bits per second that the circuit can reasonably carry as well as the interpretation of the usage and error statistics.
Settings: INTEGER
Syntax Ref. Type: ENUM
(1) = other
(2) = esf
(3) = d4
(4) = e1
(5) = e1-crc
(6) = e1-emf
(7) = e1-crc-emf
(8) = f4
(9) = f72
MIB Information: mds1CfgLineCode
1.3.6.1.4.1.429.1.36.1.1.1.7
mandatory read-write
Description: This variable describes the variety of Zero Code Suppression used on the link which in turn affects a number of its characteristics.JBZS refers the Jammed Bit Zero Suppression in which the AT&T specification of at least one pulse every 8 bit periods is literally implemented by forcing a pulse in bit 8 of each channel. Thus only seven bits per channel or 1.344 Mbps is available for data.B8ZS refers to the use of a specified pattern of normal bits and bipolar violations which are used to replace a sequence of eight zero bits.ANSI Clear Channels may use ZBTSI or Zero Byte Time Slot Interchange.E1 links with or without CRC use HDB3 or AMI.AMI refers to a mode wherein no zero code suppression is present and the line encoding does not solve the problem directly. In this which meets or exceeds the pulse density requirements such as inverting HDLC data.
Settings: INTEGER
Syntax Ref. Type: ENUM
(1) = jbzs
(2) = t1b8zs
(3) = e1hdb3
(4) = zbtsi
(5) = ami
(6) = nrz
(7) = e1cmi
MIB Information: mds1CfgLineBuildOut
1.3.6.1.4.1.429.1.36.1.1.1.8
mandatory read-write
Description: Line Build Out can be one of the following values:(1) 0 DB (2) 7.5 DB(3) 15 DB (4)22.5 DB.
Settings: INTEGER
Syntax Ref. Type: ENUM
(1) = dB0
(2) = dB075
(3) = dB15
(4) = dB225
MIB Information: mds1CfgSendCode
1.3.6.1.4.1.429.1.36.1.1.1.9
mandatory read-write
Description: This variable indicates what type of code isbeing sent across the DS1 interface by the device. The values mean:SendNoCode sending looped or normal dataSendLineCode sending a request for a line loopbackSendPayloadCode sending a request for a payload loopbackSendResetCode sending a loopback termination requestSendQRS sending a Quasi-Random Signal (QRS) test pattern Send511Pattern sending a 511 bit fixed test patternSend3in24Pattern sending a fixed test pattern of 3 bits set in 24SendOtherTestPattern sending a test pattern other than those described by this object
Settings: INTEGER
Syntax Ref. Type: ENUM
(1) = noCode
(2) = lineCode
(3) = payLoadCode
(4) = resetCode
(5) = qrs
(6) = pattern-511
(7) = in3-24-pattern
(8) = otherTestPattern
MIB Information: mds1CfgLoopBack
1.3.6.1.4.1.429.1.36.1.1.1.10
mandatory read-write
Description: This variable represents the loopback configuration of the DS1 interface. Agents supporting read/write access should return badValue in response to a requested loopback state that theinterface does not support. The values mean:NoLoopNot in the loopback state. A device that is not capable of performing a loopback on the interface shall always return this as it's value.PayloadLoopThe received signal at this interface is looped through the device. Typically the received signal is looped back for retransmission after it has passed through the device's framing function.LineLoopThe received signal at this interface does not go through the device (minimum penetration) but is looped back out.OtherLoopLoopbacks that are not defined here.
Settings: INTEGER
Syntax Ref. Type: ENUM
(1) = noLoopback
(2) = payLoadLoopBack
(3) = lineLoopBack
(4) = otherLoopBack
(5) = channelLoopBack
(6) = remoteLoopBack
(7) = localLoopBack
(1) = none
(2) = robbed-bit
(3) = bit-oriented
MIB Information: mds1CfgSignallingMode
1.3.6.1.4.1.429.1.36.1.1.1.11
mandatory read-write
Description: 'none' indicates that no bits are reserved for signaling on this channel.'robbedBit' indicates that T1 Robbed Bit Signaling is in use.'bitOriented' indicates that E1 Channel Associated Signaling is in use.'messageOriented' indicates that Common Channel Signaling is in use either on channel 16 of an E1 link or channel 24 of a T1.
Settings: INTEGER
Syntax Ref. Type: ENUM
(4) = message-oriented
MIB Information: mds1CfgTxClkSrc
1.3.6.1.4.1.429.1.36.1.1.1.12
mandatory read-write
Description: The source of Tranmit Clock.'loopTiming' indicates that the recovered receive clock is used as the transmit clock.'localTiming' indicates that a local clock source is used.'throughTiming' indicates that recovered receive clock from another interface is used as the transmit clock.
Settings: INTEGER
Syntax Ref. Type: ENUM
(1) = loopTimming
(2) = localTimming
(3) = throughTimming
MIB Information: mds1CfgFdlType
1.3.6.1.4.1.429.1.36.1.1.1.13
mandatory read-write
Description: This bitmap describes the use of the facilities data link and is the sum of the capabilities:'other' indicates that a protocol other than one following is used.'Ansi-T1-403' refers to the FDL exchange recommended by ANSI.'Att-54016' refers to ESF FDL exchanges.'none' indicates that the device does not use the FDL.
Settings: INTEGER
Syntax Ref. Type: ENUM
(1) = other
(2) = ansi-T1-403
(3) = att-54016
(4) = none
MIB Information: mds1CfgCableLen
1.3.6.1.4.1.429.1.36.1.1.1.14
mandatory read-write
Description: One of the following lengths:(1) 0 TO 131FEET(2) 131 TO 262FEET(3) 262 TO 393FEET(4) 393 TO 524FEET(5) 524 TO 655FEET(6) 655 TO 786FEET(7) LONGHAUL
Settings: INTEGER
Syntax Ref. Type: ENUM
(1) = frm0TO133Feet
(2) = frm131TO262Feet
(3) = frm262TO393Feet
(4) = frm393TO524Feet
(5) = frm524TO655Feet
(6) = frm655TO786Feet
(7) = longHaul
MIB Information: mds1CfgMaxNumPipes
1.3.6.1.4.1.429.1.36.1.1.1.15
mandatory read-write
Description: Maximum number of pipes per T1 span
Settings: INTEGER
Syntax Ref. Type: RANGE
1 = 32
MIB Information: mds1CfgNumCalls
1.3.6.1.4.1.429.1.36.1.1.1.16
mandatory read-write
Description: Maximum number of calls per pipe
Settings: INTEGER
Syntax Ref. Type: RANGE
1 = 31
MIB Information: mds1CfgSignallingType
1.3.6.1.4.1.429.1.36.1.1.1.17
mandatory read-write
Description: One of the following signaling types:(1) in band(2) out of band
Settings: INTEGER
Syntax Ref. Type: ENUM
(1) = inBand
(2) = outOfBand
MIB Information: mds1CfgSignallingTypeOpr
1.3.6.1.4.1.429.1.36.1.1.1.18
mandatory read-only
Description: One of the following signaling types:(1) in band(2) out of band. This is the operational value.
Settings: INTEGER
Syntax Ref. Type: ENUM
(1) = inBand
(2) = outOfBand
MIB Information: mds1CfgOMCRID
1.3.6.1.4.1.429.1.36.1.1.1.19
mandatory read-write
Description: Provides ability for IWU to select an alternate T1 span within the same packet zone.
Settings: INTEGER
Copyright © 2000 3Com Corporation.