MIB Information: hdmCc
1.3.6.1.4.1.429.1.22.4
MIB Information: hdmCcTable
1.3.6.1.4.1.429.1.22.4.1
not-accessible
Description: A table containing the call control parameters for each modem in the chassis.
MIB Information: hdmCcEntry
1.3.6.1.4.1.429.1.22.4.1.1
not-accessible
Description: Call control parameters for a modem. These define the sequence of operation related to how a call is negotiated.
MIB Information: hdmCcIndex
1.3.6.1.4.1.429.1.22.4.1.1.1
mandatory read-only
Description: The index which uniquely identifies the modem to which this entry is applicable. The value corresponds to the value of the index to the entity table in the chassis MIB that corresponds to the same modem.
Settings: INTEGER
MIB Information: hdmCcIndex2
1.3.6.1.4.1.429.1.22.4.1.1.2
mandatory read-only
Description: The Secondary index which uniquely identifies the modem to which this entry is applicable. The value corresponds to the value of the index to the entity table in the chassis MIB that corresponds to the same modem.
Settings: INTEGER
MIB Information: hdmCcDialDelay
1.3.6.1.4.1.429.1.22.4.1.1.3
mandatory read-write
Description: Defines the number of seconds the modem waits between going off hook and beginning to dial. Ignored when result code options 246or 7 are active. Default=2.
Settings: INTEGER
Syntax Ref. Type: RANGE
0 = 255
MIB Information: hdmCcWaitForCarrier
1.3.6.1.4.1.429.1.22.4.1.1.4
mandatory read-write
Description: Defines the number of seconds the modem will wait for a carrier signal after dialing. Default=60.
Settings: INTEGER
Syntax Ref. Type: RANGE
0 = 255
MIB Information: hdmCcInactivityTimer
1.3.6.1.4.1.429.1.22.4.1.1.5
mandatory read-write
Description: Sets the duration (in seconds) that the modem will maintain a connection when there is no activity on the phone line. The feature is disabled when set to 0. Default=0.
Settings: INTEGER
Syntax Ref. Type: RANGE
0 = 255
MIB Information: hdmCcQuietResultCodes
1.3.6.1.4.1.429.1.22.4.1.1.6
mandatory read-write
Description: Determines whether or not the modem transmits result codes to the DTE. Default=displayResult(1).
Settings: INTEGER
Syntax Ref. Type: ENUM
(1) = displayResult
(2) = noResult
(3) = originateOnly
MIB Information: hdmCcResponseMode
1.3.6.1.4.1.429.1.22.4.1.1.7
mandatory read-write
Description: Determines whether the modem transmits result codes in the verbal or numeric mode. Default=verbal(2).
Settings: INTEGER
Syntax Ref. Type: ENUM
(1) = numeric
(2) = verbal
MIB Information: hdmCcResultCodeOptions
1.3.6.1.4.1.429.1.22.4.1.1.8
mandatory read-write
Description: Defines one of eight result code subsets and also defines indirectly how the modem reacts to dial tone etc. Equates to the modem's X register Default=1.
Settings: INTEGER
Syntax Ref. Type: RANGE
0 = 7
MIB Information: hdmCcArqResultCodeMode
1.3.6.1.4.1.429.1.22.4.1.1.9
mandatory read-write
Description: Defines whether or not the ARQ result codes are sent to the DTE on connection(if result codes are enabled). Default=arqResultsEnabled(2).
Settings: INTEGER
Syntax Ref. Type: ENUM
(1) = arqResultsDisabled
(2) = arqResultsEnabled
(3) = includeHstV32
(4) = includeProtocol
MIB Information: hdmCcEscCodeRsp
1.3.6.1.4.1.429.1.22.4.1.1.10
mandatory read-write
Description: Defines the action of the modem in response to the escape code(+++). The default value is determined by the state of Dip switch 2-3 on power up.
Settings: INTEGER
Syntax Ref. Type: ENUM
(1) = goOnHook
(2) = enterCommandMode
(3) = ignoreEscCode
MIB Information: hdmCcAtRecognition
1.3.6.1.4.1.429.1.22.4.1.1.11
mandatory read-write
Description: Determines which if any AT commands the modem will recognize or accept from the DTE. Default=enableAll(3).
Settings: INTEGER
Syntax Ref. Type: ENUM
(1) = ignore
(2) = queryOnly
(3) = enableAll
MIB Information: hdmCcV32ToneDuration
1.3.6.1.4.1.429.1.22.4.1.1.12
mandatory read-write
Description: Specifies the duration (in 10ths of a second) that the modem transmits the 3000/600 Hz answer tones for V.32 handshaking. A setting of 0 eliminates these tones and will result in faster connect times for V.21 and V.23 calls. Default=8.
Settings: INTEGER
Syntax Ref. Type: RANGE
0 = 255
MIB Information: hdmCcAutoAnswer
1.3.6.1.4.1.429.1.22.4.1.1.14
mandatory read-write
Description: Determines the number of rings that the modem will answer calls on. When set to 0 the modem can only originate calls. Default=1.
Settings: INTEGER
Syntax Ref. Type: RANGE
0 = 255
MIB Information: hdmCcAnswerInOrigMode
1.3.6.1.4.1.429.1.22.4.1.1.15
mandatory read-write
Description: When enabled the modem will answer calls using the sequence normally used by the originating modem. Default=disable(1).
Settings: INTEGER
Syntax Ref. Type: ENUM
(1) = disable
(2) = enable
MIB Information: hdmCcPhoneString0
1.3.6.1.4.1.429.1.22.4.1.1.16
mandatory read-write
Description: Phone number stored in modem's non volatile memory. Useful in providing quick access to frequently called numbers. In addition mdmCcPhoneString0 is used for the dial on power up and dial on DTR options.
Settings: DisplayString
Syntax Ref. Type: SIZE
0 = 36
MIB Information: hdmCcPhoneString1
1.3.6.1.4.1.429.1.22.4.1.1.17
mandatory read-write
Description: Phone number stored in the modem's non volatile memory useful for providing quick access to frequently called numbers.
Settings: DisplayString
Syntax Ref. Type: SIZE
0 = 36
MIB Information: hdmCcPhoneString2
1.3.6.1.4.1.429.1.22.4.1.1.18
mandatory read-write
Description: Phone number stored in the modem's non volatile memory useful in providing quick access to frequently called numbers.
Settings: DisplayString
Syntax Ref. Type: SIZE
0 = 36
MIB Information: hdmCcPhoneString3
1.3.6.1.4.1.429.1.22.4.1.1.19
mandatory read-write
Description: Phone number stored in the modem's non volatile memory useful in providing quick access to frequently called numbers.
Settings: DisplayString
Syntax Ref. Type: SIZE
0 = 36
MIB Information: hdmCcErrorCntlMode
1.3.6.1.4.1.429.1.22.4.1.1.20
mandatory read-write
Description: Defines if the modem is operating in synchronous or asynchronous mode and how it responds relative to negotiation of error control on asynchronous connections. When set to the default normalArq(3) the modem attempts to connect with error control but if unable to negotiate it connects anyway. When set to none(1) async connections do not attempt to use error control. When set to arqOnly(4) the modem will hang up if unable to negotiate error control. When set to syncMode(2) the modem will not connect asynchronously.
Settings: INTEGER
Syntax Ref. Type: ENUM
(1) = none
(2) = syncMode
(3) = normalArq
(4) = arqOnly
(5) = v25bisChar
(6) = v25bisBit
MIB Information: hdmCcMnpWith1200
1.3.6.1.4.1.429.1.22.4.1.1.21
mandatory read-write
Description: Determines if the modem will include MNP/V42 negotiation on 1200 bps connections. Default=enable(1).
Settings: INTEGER
Syntax Ref. Type: ENUM
(1) = enable
(2) = disable
MIB Information: hdmCcMnpWith2400
1.3.6.1.4.1.429.1.22.4.1.1.22
mandatory read-write
Description: Determines if the modem will include MNP/V43 negotiation on 2400 bps calls. default=enable(1).
Settings: INTEGER
Syntax Ref. Type: ENUM
(1) = enable
(2) = disable
MIB Information: hdmCcMnpWithV32
1.3.6.1.4.1.429.1.22.4.1.1.23
mandatory read-write
Description: Determines if the modem will include MNP/V42 negotiation on V.32 connections. Default=enable(1).
Settings: INTEGER
Syntax Ref. Type: ENUM
(1) = enable
(2) = disable
MIB Information: hdmCcMnpTimeout
1.3.6.1.4.1.429.1.22.4.1.1.24
mandatory read-write
Description: Specifies the MNP/V42 link request timeout for negotiation of 1200 and 2400 bps calls. Default=5.
Settings: INTEGER
Syntax Ref. Type: RANGE
0 = 14
MIB Information: hdmCcV21V23FallBackTimer
1.3.6.1.4.1.429.1.22.4.1.1.25
mandatory read-write
Description: V21/V23 fallback timer 1/10 sec. NVRAM S Register S29. Default=20
Settings: INTEGER
Syntax Ref. Type: RANGE
0 = 255
MIB Information: hdmCcAddnlAnswToneDur
1.3.6.1.4.1.429.1.22.4.1.1.26
mandatory read-write
Description: Additional answer tone duration 1/10 sec. NVRAM S Register S49. Default=16.
Settings: INTEGER
Syntax Ref. Type: RANGE
0 = 255
MIB Information: hdmCcBillingDelayPeriod
1.3.6.1.4.1.429.1.22.4.1.1.27
mandatory read-write
Description: Billing Delay Period. 1/50 sec. NVRAM S Register S50. Default=100.
Settings: INTEGER
Syntax Ref. Type: RANGE
0 = 255
MIB Information: hdmCcCarrierAccessCode1
1.3.6.1.4.1.429.1.22.4.1.1.28
optional read-write
Description: The DNIS Carrier Access Code (CAC) Number. This is a string which contains a number from 1 to 10 digits (e.g. 9501755). This is the 1st of 3 CACs.
Settings: DisplayString
Syntax Ref. Type: SIZE
0 = 10
MIB Information: hdmCcCarrierAccessCode2
1.3.6.1.4.1.429.1.22.4.1.1.29
optional read-write
Description: The DNIS Carrier Access Code (CAC) Number. This is a string which contains a number from 1 to 10 digits. This is the 2nd of 3 CACs.
Settings: DisplayString
Syntax Ref. Type: SIZE
0 = 10
MIB Information: hdmCcCarrierAccessCode3
1.3.6.1.4.1.429.1.22.4.1.1.30
optional read-write
Description: The DNIS Carrier Access Code (CAC) Number. This is a string which contains a number from 1 to 10 digits. This is the 3rd of 3 CACs.
Settings: DisplayString
Syntax Ref. Type: SIZE
0 = 10
MIB Information: hdmCcCallingInitStr1
1.3.6.1.4.1.429.1.22.4.1.1.31
optional read-write
Description: This is the Carrier Access Code (CAC) initialization string. This string is a configuration string of 1 to 30 characters (e.g. &F &F&B1&R1 etc.) This string does NOT include the AT attention prefix. This is the 1st of 4 CAC init strings.
Settings: DisplayString
Syntax Ref. Type: SIZE
0 = 40
MIB Information: hdmCcCallingInitStr2
1.3.6.1.4.1.429.1.22.4.1.1.32
optional read-write
Description: This is the Carrier Access Code (CAC) initialization string. This string is 1 to 30 characters. It does NOT include the AT attention prefix. It is the 2nd of 4 CAC init strings.
Settings: DisplayString
Syntax Ref. Type: SIZE
0 = 40
MIB Information: hdmCcCallingInitStr3
1.3.6.1.4.1.429.1.22.4.1.1.33
optional read-write
Description: This is the Carrier Access Code (CAC) initialization string. This is a string of 1 to 30 characters. It does NOT include the AT attention prefix. This is the 3rd of 4 CAC init strings.
Settings: DisplayString
Syntax Ref. Type: SIZE
0 = 40
MIB Information: hdmCcCallingInitStr4
1.3.6.1.4.1.429.1.22.4.1.1.34
optional read-write
Description: This is the Carrier Access Code (CAC) initialization string. This is a string of 1 to 30 characters. It does NOT include the AT attention prefix. This is the 4th of 4 CAC init strings.
Settings: DisplayString
Syntax Ref. Type: SIZE
0 = 40
MIB Information: hdmCcT1CallSetupProc
1.3.6.1.4.1.429.1.22.4.1.1.35
optional read-write
Description: Determines T1 call setup procedures used. Choices are 'normal' or 'none'. None assumes a dedicated (leased) DS0 assigned to the modem.Default=normalSetup(1).
Settings: INTEGER
Syntax Ref. Type: ENUM
(1) = normalSetup
(2) = noSetup
MIB Information: hdmCcT1KpStMfTones
1.3.6.1.4.1.429.1.22.4.1.1.36
optional read-write
Description: Determines the usage of KP and ST MF tone encapsulation of the dial sequence.Default=enable(1).
Settings: INTEGER
Syntax Ref. Type: ENUM
(1) = enable
(2) = disable
MIB Information: hdmCcT1CallInitStrUse
1.3.6.1.4.1.429.1.22.4.1.1.37
optional read-write
Description: Determines if calling init strings are used or not.Default=enable(1).
Settings: INTEGER
Syntax Ref. Type: ENUM
(1) = enable
(2) = disable
MIB Information: hdmCcT1CallInitStrBase
1.3.6.1.4.1.429.1.22.4.1.1.38
optional read-write
Description: Determines if the calling init strings are based upon DNIS or ANI.Default=dnisBase(1).
Settings: INTEGER
Syntax Ref. Type: ENUM
(1) = dnisBase
(2) = aniBase
MIB Information: hdmCcT1DialInAniDig
1.3.6.1.4.1.429.1.22.4.1.1.39
optional read-write
Description: Sets the number of ANI digits allowed in incoming calls. Default = 0.
Settings: INTEGER
Syntax Ref. Type: RANGE
0 = 12
MIB Information: hdmCcT1DialInDnisDig
1.3.6.1.4.1.429.1.22.4.1.1.40
optional read-write
Description: Sets the number of DNIS/DID digits allowed in incoming calls. Default = 0.
Settings: INTEGER
Syntax Ref. Type: RANGE
0 = 12
MIB Information: hdmCcDataOverVoice
1.3.6.1.4.1.429.1.22.4.1.1.41
mandatory read-write
Description: Data Over Voice support.
Settings: INTEGER
Syntax Ref. Type: ENUM
(1) = disable
(2) = enable
MIB Information: hdmCc2100AnswerTone
1.3.6.1.4.1.429.1.22.4.1.1.42
mandatory read-write
Description: 2100 Hz Answer Tone for DOVBS.
Settings: INTEGER
Syntax Ref. Type: ENUM
(1) = disable
(2) = enable
MIB Information: hdmCcEnableV120v42Bis
1.3.6.1.4.1.429.1.22.4.1.1.43
mandatory read-write
Description: V.42bis Compression over V.120.
Settings: INTEGER
Syntax Ref. Type: ENUM
(1) = disable
(2) = enable
Copyright © 2000 3Com Corporation.