imdmCc

MIB Information: imdmCc
1.3.6.1.4.1.429.1.19.1

imdmCcTable

MIB Information: imdmCcTable
1.3.6.1.4.1.429.1.19.1.1
not-accessible

Description: A table containing the call control parameters for each modem in the chassis.

imdmCcEntry

MIB Information: imdmCcEntry
1.3.6.1.4.1.429.1.19.1.1.1
not-accessible

Description: Call control parameters for an ISDN modem. These define the sequence of operation related to how a call is negotiated.

imdmCcIndex

MIB Information: imdmCcIndex
1.3.6.1.4.1.429.1.19.1.1.1.1
mandatory read-only

Description: The index which uniquely identifies the modem to which this entry is applicable. The value corresponds to the value of the index to the entity table in the chassis MIB that corresponds to the same modem.

Settings: INTEGER

imdmCcRateAdapV110

MIB Information: imdmCcRateAdapV110
1.3.6.1.4.1.429.1.19.1.1.1.2
mandatory read-write

Description: This object enables V110 rate adaption corresponds to S register S67 bit 0. Default = enable(2).

Settings: INTEGER

Syntax Ref. Type: ENUM

(1) = disable
(2) = enable

imdmCcFixedNtwkRate

MIB Information: imdmCcFixedNtwkRate
1.3.6.1.4.1.429.1.19.1.1.1.3
mandatory read-write

Description: This object sets the fixed network rate. This object correspond to S register S67 bit 1. Default = 1

Settings: INTEGER

Syntax Ref. Type: ENUM

(1) = notForced
(2) = forceNetworkRate

imdmCcNetworkRate

MIB Information: imdmCcNetworkRate
1.3.6.1.4.1.429.1.19.1.1.1.4
mandatory read-write

Description: This object sets the Network rate speed. This object corresponds to the modem S register S67 bit 2. Default = 1

Settings: INTEGER

Syntax Ref. Type: ENUM

(1) = kbps56
(2) = kbps64

imdmCcBcLinkDly

MIB Information: imdmCcBcLinkDly
1.3.6.1.4.1.429.1.19.1.1.1.5
mandatory read-write

Description: This object enable a 45 - 65 second link delay. This object corresponds to the S register S67 bit 4. Default = 1

Settings: INTEGER

Syntax Ref. Type: ENUM

(1) = noDelay
(2) = delay

imdmCcAnlgOvrDig

MIB Information: imdmCcAnlgOvrDig
1.3.6.1.4.1.429.1.19.1.1.1.6
mandatory read-write

Description: This object is used to set S register S68 bit 0 which does not allow analog calls over digital data connection. Default = 1

Settings: INTEGER

Syntax Ref. Type: ENUM

(1) = enable
(2) = disable

imdmCcAsyncPPP

MIB Information: imdmCcAsyncPPP
1.3.6.1.4.1.429.1.19.1.1.1.7
mandatory read-write

Description: This object is used to disable/enable async PPP/ sync PPP conversion. This object corresponds to S register S68 bit 2. Default = enable(1).

Settings: INTEGER

Syntax Ref. Type: ENUM

(1) = enable
(2) = disable

imdmCcX75

MIB Information: imdmCcX75
1.3.6.1.4.1.429.1.19.1.1.1.8
mandatory read-write

Description: This object is used to disable/enable X75. This object corresponds to S register S68 bit 3. Default = 1

Settings: INTEGER

Syntax Ref. Type: ENUM

(1) = enable
(2) = disable

imdmCcStarV2

MIB Information: imdmCcStarV2
1.3.6.1.4.1.429.1.19.1.1.1.9
mandatory read-write

Description: This object is used to set the data mode of the modem and is equivalent to *V2 = x AT command. Default =1

Settings: INTEGER

Syntax Ref. Type: ENUM

(1) = autodetect
(2) = v120rateAdapOnly
(3) = v110rateAdapOnly
(4) = modemOrFaxOnly
(5) = clearChannelSync
(6) = asyncSyncPPPconv
(7) = x75

imdmCcStarU1

MIB Information: imdmCcStarU1
1.3.6.1.4.1.429.1.19.1.1.1.10
mandatory read-write

Description: This object is used to set the originate HDLC protocols of the modem and is equivalent to *U1 = x AT command. Default =2

Settings: INTEGER

Syntax Ref. Type: ENUM

(1) = none
(2) = v120
(3) = x75
(4) = ppp

imdmCcStarU2

MIB Information: imdmCcStarU2
1.3.6.1.4.1.429.1.19.1.1.1.11
mandatory read-write

Description: This object is used to set the originate Non-HDLC protocols of the modem and is equivalent to *U2 = x AT command. Default =1

Settings: INTEGER

Syntax Ref. Type: ENUM

(1) = none
(2) = v110

imdmCcStarU3

MIB Information: imdmCcStarU3
1.3.6.1.4.1.429.1.19.1.1.1.12
mandatory read-write

Description: This object is used to set the originate Analog modem/fax data mode of the modem and is equivalent to *U3 = x AT command. Default =2

Settings: INTEGER

Syntax Ref. Type: ENUM

(1) = none
(2) = analogModemFax

imdmCcV120

MIB Information: imdmCcV120
1.3.6.1.4.1.429.1.19.1.1.1.13
mandatory read-write

Description: This Object is used to Enable/Disable V120. This Object corresponds to S register 68 bit 4 default=1

Settings: INTEGER

Syntax Ref. Type: ENUM

(1) = enable
(2) = disable

imdmCcFrameSize

MIB Information: imdmCcFrameSize
1.3.6.1.4.1.429.1.19.1.1.1.14
mandatory read-write

Description: This Object is used to set the Frame size for X75. Default = 2048

Settings: INTEGER

Syntax Ref. Type: RANGE

1 = 2048

imdmCcWindowSize

MIB Information: imdmCcWindowSize
1.3.6.1.4.1.429.1.19.1.1.1.15
mandatory read-write

Description: This Object is used to set the Window Size of X75 default=2

Settings: INTEGER

Syntax Ref. Type: RANGE

1 = 7





Copyright © 2000 3Com Corporation.