sdhGeneral

MIB Information: sdhGeneral
1.3.6.1.4.1.429.1.46.1

sdhGeneralTable

MIB Information: sdhGeneralTable
1.3.6.1.4.1.429.1.46.1.1
not-accessible

Description: The SDH Line Level General Table.

sdhGeneralEntry

MIB Information: sdhGeneralEntry
1.3.6.1.4.1.429.1.46.1.1.1
not-accessible

Description: An entry in the SDH Line Level General Table.

sdhGeneralIndex

MIB Information: sdhGeneralIndex
1.3.6.1.4.1.429.1.46.1.1.1.1
mandatory read-only

Description: Index for the General Table at the SDH Line Level.

Settings: INTEGER

sdhMediumType

MIB Information: sdhMediumType
1.3.6.1.4.1.429.1.46.1.1.1.2
obsolete read-only

Description: This object contains type of Slot in PCB. 0x0001=SONET 0x0002=SDH.

Settings: INTEGER

Syntax Ref. Type: ENUM

(1) = sonet
(2) = sdh

sdhMediumLoopbackConfig

MIB Information: sdhMediumLoopbackConfig
1.3.6.1.4.1.429.1.46.1.1.1.3
mandatory read-write

Description: This object contains the current loopback state of SDH interface.0x0001=No Loop0x0002=Facility Loop0x0003=Terminal Loop0x0004=Optical Loop.

Settings: INTEGER

Syntax Ref. Type: ENUM

(1) = noLoop
(2) = facilityLoop
(3) = terminalLoop
(4) = opticalLoop

sdhHighPathCurrentWidth

MIB Information: sdhHighPathCurrentWidth
1.3.6.1.4.1.429.1.46.1.1.1.4
mandatory read-only

Description: This object indicates the type of SDH interface. 0x0001=STM-0 0x0002=STM-10x0003=STM-40x0004=dc0x00005=STM-16

Settings: INTEGER

Syntax Ref. Type: ENUM

(1) = stm0
(2) = stm1
(3) = stm4
(4) = dc
(5) = stm16

sdhVTCurrentWidth

MIB Information: sdhVTCurrentWidth
1.3.6.1.4.1.429.1.46.1.1.1.5
mandatory read-only

Description: This object indicates the type of SDH Low Path. 0x0001=VC11 0x0002=VC120x0003=vtWidth30x0004=VC20x00005=vtWidth6c

Settings: INTEGER

Syntax Ref. Type: ENUM

(1) = vc11
(2) = vc12
(3) = vtWidth3
(4) = vc2
(5) = vtWidth6c

sdhSideInformation

MIB Information: sdhSideInformation
1.3.6.1.4.1.429.1.46.1.1.1.6
mandatory read-only

Description: This object indicates side of data collection. 0x0001=side-0 0x0002=side-1

Settings: INTEGER

Syntax Ref. Type: ENUM

(1) = side0
(2) = side1

sdhServiceCmdForce

MIB Information: sdhServiceCmdForce
1.3.6.1.4.1.429.1.46.1.1.1.7
mandatory read-write

Description: This object contains a value that identifies the command being requested. 0x0001=no command 0x0002=FS switch release 0x0003=CNV-SBY (FS Switch Order) 0x0004=CNV-ACT(compulsive ACT order(receive at other-side communication NG))

Settings: INTEGER

Syntax Ref. Type: ENUM

(1) = noCommand
(2) = fsSwitchRelease
(3) = cnvSby
(4) = cnvAct

sdhCnvCardState

MIB Information: sdhCnvCardState
1.3.6.1.4.1.429.1.46.1.1.1.8
mandatory read-only

Description: This object contains state of SDH converter card. 0x0001=CNV-OUS 0x0002=CNV-SBY0x0003=CNV-ACT

Settings: INTEGER

Syntax Ref. Type: ENUM

(1) = cnvOus
(2) = cnvSby
(3) = cnvAct

sdhCardOperationMode

MIB Information: sdhCardOperationMode
1.3.6.1.4.1.429.1.46.1.1.1.9
mandatory read-write

Description: This object contains a value that identifies the command being requested.INS/OUS order of SDH Converter Card.0x0001=no command 0x0002=CNV-OUS0x0003=CNV-INS

Settings: INTEGER

Syntax Ref. Type: ENUM

(1) = noCommand
(2) = cnvOus
(3) = cnvIns

sdhMediumTimeElapsed

MIB Information: sdhMediumTimeElapsed
1.3.6.1.4.1.429.1.46.1.1.1.10
mandatory read-only

Description: The number of secondsincluding partial secondsthat have elapsed since the beginning of the current measurement period.0x0000=0 sec 0x0384=900 sec.

Settings: INTEGER

Syntax Ref. Type: RANGE

0 = 900

sdhMediumValidIntervals

MIB Information: sdhMediumValidIntervals
1.3.6.1.4.1.429.1.46.1.1.1.11
mandatory read-only

Description: Content of 24 hours collection counter 0x0000--0x0060=0--96

Settings: INTEGER

Syntax Ref. Type: RANGE

0 = 96

sdhSMCurrentInterval

MIB Information: sdhSMCurrentInterval
1.3.6.1.4.1.429.1.46.1.1.1.12
mandatory read-only

Description: A number between 1 and 96which identifies the interval for which the set of statistics is available. 0x0001 --- 0x0060=1 -- 96

Settings: INTEGER

Syntax Ref. Type: RANGE

1 = 96

sdhHardFailure

MIB Information: sdhHardFailure
1.3.6.1.4.1.429.1.46.1.1.1.13
mandatory read-only

Description: Content of Hard Failure 0 bit :SOH-LSI diagnosis failure1 bit :2 bit :SOH-LSI inside-PLL failure3 bit :Diagnosis failure between SOH and VCTRM (SOH detects the failure)4---7 bits 08 bit :VCTRM-LSI diagnousis failure9 bit :Diagnosis failure between SOH and VCTRM (VCTRM detects the failure)10 bit:VCTRM-LSI parity error11 bit:VCTRM-LSI inside-PLL failure12 bit:Diagnosis failure between VCTRM and CNV-FPGA (VCTRM detects the failure)13 bit:Diagnosis failure between VCTRM and CNV-FPGA (CNV FPGA detects the failure)14--15 bits 016 bit:no output clock in outside 155M-PLL17 bit:outside 155M-PLL failure18 - 19 bits 020 bit:Telecom Bus A/B parity error21 - 31 bits 0 bit 0 is normal / bit 1 is detect

Settings: INTEGER

sdhDS3Failure

MIB Information: sdhDS3Failure
1.3.6.1.4.1.429.1.46.1.1.1.14
mandatory read-only

Description: Content of DS3 failure by detect 0 bit : between DS3-SM and SDH-AM mail receive time out1 bit : DS3 line fail bit 0 is normal / bit 1 is detect

Settings: INTEGER

sdhPathTestOrder

MIB Information: sdhPathTestOrder
1.3.6.1.4.1.429.1.46.1.1.1.16
mandatory read-write

Description: Content of Path Test Order 0x0001 = clear all test path 0x0002 = test circuit self diagnosis 0x0003 = clear DROP path 0x0004 = clear INSERT path 0x0005 = start error count measurement 0x0006 = collects of measured error count

Settings: INTEGER

Syntax Ref. Type: RANGE

1 = 6

sdhPathTestDropPathRequest

MIB Information: sdhPathTestDropPathRequest
1.3.6.1.4.1.429.1.46.1.1.1.18
mandatory read-write

Description: The receive side DROP Path order (a) kind of test path 0x01 / 0x03 = AU / TU(b) AU value 0x01 --- 0x03 = AU#1 --- AU#3(c) TUG value 0x01 --- 0x07 = TUG#1 --- TUG#7(d) TU value 0x01 --- 0x04 = TU#1 --- TU#40x00000000 = no-information

Settings: INTEGER

sdhPathTestDropPathConfigure

MIB Information: sdhPathTestDropPathConfigure
1.3.6.1.4.1.429.1.46.1.1.1.19
mandatory read-only

Description: The value which SDHSM set the request(order) DROP Path value . *4 (a) kind of test path 0x01 / 0x03 = AU / TU(b) AU value 0x01 --- 0x03 = AU#1 --- AU#3(c) TUG value 0x01 --- 0x07 = TUG#1 --- TUG#7(d) TU value 0x01 --- 0x04 = TU#1 --- TU#4 0x00000000 = no-information

Settings: INTEGER

sdhOthSideFailure

MIB Information: sdhOthSideFailure
1.3.6.1.4.1.429.1.46.1.1.1.15
mandatory read-only

Description: Content of other-side failure 0 bit :APS cable non-connect1 bit :other-side power supply failure2 bit :Heart Beat NG3 bit :04 bit :APS cable failure5---11 bits 012 bit:APS cable failure from other-side13 bit:other-side Equipment failure14 bit:state of other-side DS3 card INS/OUS (0:INS(ACT/SBY)1:OUS)15 bit:other-side DS3 line failure ( other-side DS3-SM detect )16---27 bits 028 bit:own-side detect SF29 bit:own-side detect SD 30 bit:other-side detect SF31 bit:other-side detect SD bit 0 is normal / bit 1 is detect

Settings: INTEGER

sdhPathTestStatus

MIB Information: sdhPathTestStatus
1.3.6.1.4.1.429.1.46.1.1.1.17
mandatory read-only

Description: The Path Test state of SDHSM.all 0 = initial state ( test paths are cleared )0 bit : DROP path set state1 - 3 bits 0 4 bit : INSERT path set state 5---7 bits 0 8 bit : measurement state9 bit : test circuit self diagnosis state1011 bits 0 12 bit: PN synchronism watch state 13---31 bit 0 bit 0 is OFF / bit 1 is ON

Settings: INTEGER

sdhPathTestInsertPathRequest

MIB Information: sdhPathTestInsertPathRequest
1.3.6.1.4.1.429.1.46.1.1.1.20
mandatory read-write

Description: The receive side INSERT Path order *3 (a) kind of test path 0x01 / 0x03 = AU / TU (b) AU value 0x01 --- 0x03 = AU#1 --- AU#3(c) TUG value 0x01 --- 0x07 = TUG#1 --- TUG#7(d) TU value 0x01 --- 0x04 = TU#1 --- TU#4 0x00000000 = no-information

Settings: INTEGER

sdhPathTestInsertPathConfigure

MIB Information: sdhPathTestInsertPathConfigure
1.3.6.1.4.1.429.1.46.1.1.1.21
mandatory read-only

Description: The value which SDHSM set the request(order) INSERT Path value . *4 (a) kind of test path 0x01 / 0x03 = AU / TU(b) AU value 0x01 --- 0x03 = AU#1 --- AU#3 (c) TUG value 0x01 --- 0x07 = TUG#1 --- TUG#7(d) TU value 0x01 --- 0x04 = TU#1 --- TU#40x00000000 = no-information

Settings: INTEGER

sdhPathTestResultRead

MIB Information: sdhPathTestResultRead
1.3.6.1.4.1.429.1.46.1.1.1.22
mandatory read-only

Description: Result of Path Test 0x0000 = 0 0x7FFE = 32766 (MAX) 0x7FFF = overflow 0xFFFF = ineffective

Settings: INTEGER

sdhSectionCurrentStatus

MIB Information: sdhSectionCurrentStatus
1.3.6.1.4.1.429.1.46.1.1.1.23
mandatory read-only

Description: Content of SDH Section alarme *3 0 bit : NoDefect1 bit : LOS2 bit : LOF bit 0 is normal / bit 1 is detect

Settings: INTEGER

sdhLineCurrentStatus

MIB Information: sdhLineCurrentStatus
1.3.6.1.4.1.429.1.46.1.1.1.24
mandatory read-only

Description: Content of SDH Line alarm 0 bit : NoDefect1 bit : AIS(MS-AIS)2 bit : RDI(MS-RDI) bit 0 is normal / bit 1 is detect

Settings: INTEGER

sdhSectionAlarm

MIB Information: sdhSectionAlarm
1.3.6.1.4.1.429.1.46.1.1.1.25
mandatory read-only

Description: Detect state of SDH-section alarm 0 bit : NoDefect1 bit : B1SD2 bit : B2SD3 bit : TF bit 0 is normal / bit 1 is detect

Settings: INTEGER





Copyright © 2000 3Com Corporation.