MIB Information: mdmLs
1.3.6.1.4.1.429.1.6.14
MIB Information: mdmLsTable
1.3.6.1.4.1.429.1.6.14.1
not-accessible
Description: A table defining all the Link Security parameters for each modem in the chassis.
MIB Information: mdmLsTableEntry
1.3.6.1.4.1.429.1.6.14.1.1
not-accessible
Description: Link Security parameters for a modem. These define the link level security operations which take place when a call is negotiated.
MIB Information: mdmLsIndex
1.3.6.1.4.1.429.1.6.14.1.1.1
mandatory read-only
Description: The index which uniquely identifies the modem to which this entry is applicable. The value corresponds to the value of the index to the entity table in the chassis MIB that corresponds to the same modem.
Settings: INTEGER
MIB Information: mdmLsSecurityEnable
1.3.6.1.4.1.429.1.6.14.1.1.2
mandatory read-write
Description: Allows to disable/enable the dial security feature for the modem.
Settings: INTEGER
Syntax Ref. Type: ENUM
(1) = disable
(2) = enable
MIB Information: mdmLsFallbackPromptEnable
1.3.6.1.4.1.429.1.6.14.1.1.3
mandatory read-write
Description: Disables/enables the prompting by the called modem when the auto pass password supplied by the caller fails or if no password is supplied at all.
Settings: INTEGER
Syntax Ref. Type: ENUM
(1) = disable
(2) = enable
MIB Information: mdmLsForcePromptEnable
1.3.6.1.4.1.429.1.6.14.1.1.4
mandatory read-write
Description: If this is enabled the modem will prompt the remote user for a password regardless of the success of the modem to negotiate the auto pass password.
Settings: INTEGER
Syntax Ref. Type: ENUM
(1) = disable
(2) = enable
MIB Information: mdmLsLocAccPasswdEnable
1.3.6.1.4.1.429.1.6.14.1.1.5
mandatory read-write
Description: Disables/enables the Local Access Password feature used to establish security check when accessing any security setting.
Settings: INTEGER
Syntax Ref. Type: ENUM
(1) = disable
(2) = enable
MIB Information: mdmLsDialBackEnable
1.3.6.1.4.1.429.1.6.14.1.1.6
mandatory read-write
Description: If this is set to enable the modem after successful password validation will disconnect and dial out to the originating modem.
Settings: INTEGER
Syntax Ref. Type: ENUM
(1) = disable
(2) = enable
MIB Information: mdmLsAutoPassPasswd
1.3.6.1.4.1.429.1.6.14.1.1.7
mandatory read-write
Description: Contains the Auto Pass Password used for establishing Link security during call negotiation.
Settings: DisplayString
Syntax Ref. Type: SIZE
0 = 8
MIB Information: mdmLsLocalAccessPasswd
1.3.6.1.4.1.429.1.6.14.1.1.8
mandatory read-write
Description: Contains the Local Access password used when accessing any security setting and when Local Access password feature is enabled.
Settings: DisplayString
Syntax Ref. Type: SIZE
0 = 8
MIB Information: mdmLsAccountPasswd
1.3.6.1.4.1.429.1.6.14.1.1.9
mandatory read-write
Description: Contains the fall back password which must be entered if auto pass password is not satisfied.
Settings: DisplayString
Syntax Ref. Type: SIZE
0 = 8
Copyright © 2000 3Com Corporation.